I was impressed with the prompt service I received....THE SAME DAY! Rambelt Gomez was very friendly, professional and courteous. I felt I was speaking with someone who knew what he was doing. He is very knowledgeable. Inspected my problem closely and gave me a solution immediately. Nothing was too big for him!! I will call MY ELECTRICIAN with any future problems I may encounter in the future...
No problems, here on time, every thing good
I would recommend Rembelt Gomez to anyone who needs electrical services
Rembelt Gomez is very courteous, knowledgeable and professional.
My problem was fixed professionally and quickly! Thank you!
Found the exterior outlet s not working .in the garage found tripped GFCI outlet reset all power restored,showed customer where to reset GFCI outlet.iIn the closet under the stairway installed a 1 gang cut in box ,wire receptacle and wall plate,tied into existing closet circuit,all tests good.
Replaced old broken post light with new post light tested photocell all is working properly at this time
Replaced and upgraded re outlet and checked the wires.
Installed a GFCI receptacle with weatherproof box and cover for outside sitting area
Upgraded grounding system to 2 ground rods and bridge. Also upgraded smoke detector system.
Home maintenance was done found a bad GFCI in restroom replaced it with a new self test GFCI also found a missing smoke detector and installed a new AC\DC smoke detector
Check under the Home for possums and strip the wires did not find any strip the wires the receptacle that the client claimed was not working was just a switched receptacle that she had turned off.
Went to the customers home to verify the work was completed from his home inspection.checked wires in the hot water heater and electrical panel all work was completed correctly.customer now has hot water.While in the panel found a circuit with the incorrect breaker size for that circuit also found a melted outlet on that circuit.installed new breaker and outlet all tested good
Found a bad receptacle that was cutting the circuit off for the kitchen and dine room. Corrected a GE breaker that was in a eaton panel to the proper eaton breaker.
Found no power to the a/c exterior unit.in the exterior panel of the home found faulty 2 pole 40 amp Gould breaker in the Cutler Hammerpanel .the name plate on the A/C unit said max fused for the unit identified on the label is 45 amps installed Cutler Hammer 2 pole 45 amp breaker.turned thermostat down unit now runs correctly.
Upgraded old rusted and burned panel with new out door weatherproof panel surge and ground system.
Upgraded old T 12 ballast and bulbs with all new brighter LED retrofit kit
Upgraded old T 12 ballast and bulbs with all new brighter LED retrofit kit
Upgraded old T 12 ballast and bulbs with all new brighter LED retrofit kit
Found no power to multiple outlets around the home.found tripped GFCI outlet in the garage that customer wasn't aware of reset GFCI power was restored to the bathrooms.On the back patio grilling area found 2 faulty GFCi outlets replaced both outlets with new tamper proof GFCI outlets all tested good .gave customer 5 percent military discount thanking him for his service to the country.